Commercial Kitchens Archives - Medem UK Ltd. https://medem.co.uk/product-category/commercial-kitchens/ Leading supplier and Manufacturer of Gas Detection equipment. Sun, 07 Jul 2019 19:16:50 +0000 en-GB hourly 1 https://wordpress.org/?v=6.4.3 https://medem.co.uk/wp-content/uploads/2018/10/cropped-Favacon-1-32x32.png Commercial Kitchens Archives - Medem UK Ltd. https://medem.co.uk/product-category/commercial-kitchens/ 32 32 CM2L-K https://medem.co.uk/product/cm2l-k/ Wed, 17 Apr 2019 17:19:13 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=1704 The CM2L-K is a two-channel current monitor designed for use with Medem ventilation interlock systems.

Featuring an OLED display and simple button press learn feature makes the CM2L-K current monitor quick and simple to set-up.

Flexibility
Each CM2L-K can be used to interlock 2 fans, the fans are connected by taking the live feed for each fan through the current monitor (before any speed controllers/inverters).

Fan load sensitivity range on each fan is 30 milliamps to 24 amps (max).

CM2L-K with button learn-function without an LCD is also available.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

 

The post CM2L-K appeared first on Medem UK Ltd..

]]>
> Compact <
> Clear OLED Display<
> Simple button press to learn feature<
> Wide monitoring range <
> Multiple units can be series wired <

Large sensitivity range, 30 milliamps to 24 amps (max).
Can be used with 3 phase by selecting a single phase to monitor.

 


Product and Installation Guides
⤓ CM2L-K | Product and Installation Guide

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post CM2L-K appeared first on Medem UK Ltd..

]]>
SafeAir CM (GP) https://medem.co.uk/product/safeair-cm-gp/ Wed, 20 Feb 2019 14:13:47 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=1012 The SafeAir CM GP offers a simple single panel package for ventilation interlocking a commercial kitchen to aid sites in meeting BS6173:2009 and IGEM/UP19.

It can also monitor for air quality when fitted with the required detectors with carbon dioxide PPM levels displayed on the LCD.

It features gas pressure proving and built-in two-channel current monitor designed for use within commercial kitchens, set up with a simple button press.

Gas proving must be fitted in any commercial kitchen which has appliances fitted without flame failure devices (FFD’s). As explained further in the article “why fit gas pressure proving in a commercial kitchen?” gas proving should be considered for the long term benefit and safety of the site when considering other gas standards and that the majority of leaks identified are before the FFD’s.

The easy to use OLED provides clear messages giving real-time information rather than just LED indications.

Fan load sensitivity range on each fan is 30 milliamps to 20 amps (max).


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

Download the catalogue:


⤓ SafeAir Range | Short Catalogue

 

 

 

The post SafeAir CM (GP) appeared first on Medem UK Ltd..

]]>
> In-built two-channel current monitoring <
> Simple button press learn feature for current monitoring set-up <
> Gas proving with Engineers features <
> 1 to 4 detectors <
> OLED display <
> Settable SELV relay (Low/High Alarm, Detector Alert, EM stop & Gas On conditions) <
> EM stop & Fire Alarm monitoring <

Panel mounted Emergency Stop Button with a facility to monitor remote buttons.


Product and Installation Guides
⤓ SafeAir CM (GP) | Product and Installation Guide



Related Standards
 > BS6173
 > UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post SafeAir CM (GP) appeared first on Medem UK Ltd..

]]>
SafeAir CM https://medem.co.uk/product/safeair-cm/ Wed, 20 Feb 2019 13:23:12 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=1010 The SafeAir CM offers a simple single panel package for ventilation interlocking a commercial kitchen to aid sites in meeting BS6173:2009 and IGEM/UP19.

The SafeAir CM offers a simple single panel package for ventilation interlocking a commercial kitchen to aid sites in meeting BS6173:2009 and IGEM/UP19.

It can also monitor for air quality when fitted with the required detectors with carbon dioxide PPM levels displayed on the LCD.

It features built-in two-channel current monitor designed for use within commercial kitchens, set up with a simple button press.

The easy to use OLED provides clear messages giving real-time information rather than just LED indications.

Fan load sensitivity range on each fan is 30 milliamps to 20 amps (max).


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

Download the catalogue:


⤓ SafeAir Range | Short Catalogue

 

 

The post SafeAir CM appeared first on Medem UK Ltd..

]]>
> In-built two channel current monitoring <
> Simple button press learn feature for current set-up <
> Engineers features <
> 1 to 4 detectors <
> OLED display <
> Settable SELV relay (Low/High Alarm, Detector Alert, EM stop & Gas On conditions) <
> EM stop & Fire Alarm monitoring <

Panel mounted Emergency Stop Button with facility to monitor remote buttons.

 


Product and Installation Guides
⤓ SafeAir CM | Product and Installation Guide



Related Standards
 > BS6173
 > UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post SafeAir CM appeared first on Medem UK Ltd..

]]>
SafeAir (GP) https://medem.co.uk/product/safeair-gp/ Wed, 20 Feb 2019 13:13:04 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=1008 The SafeAir (GP) offers a simple cost-effective panel for ventilation interlocking and gas pressure proving in a commercial kitchen.

It is designed for use within commercial kitchens, to aid sites in meeting BS6173:2009 and IGEM/UP19. It can also monitor for air quality when fitted with the required detectors with carbon dioxide PPM levels displayed on the LCD.

Gas proving must be fitted in any commercial kitchen which has appliances fitted without flame failure devices (FFD’s). As explained further in the article “why fit gas pressure proving in a commercial kitchen?” gas proving should be considered for the long-term benefit and safety of the site when considering other gas standards and that the majority of leaks identified are before the FFD’s.

The easy to use LCD provides clear messages giving real-time information rather than just LED indications.

It is a requirement that any mechanical ventilation within a kitchen environment (both supply and extract) is switched on and running before the use of any gas appliances can take place. With the SafeAir (GP), if the ventilation is not switched on, the LCD display informs the operator that the fans are off.

For the interlocking of the ventilation, our current monitoring units (CM2M-K or CM2L-K) or pressure differential switches can be used.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

Download the catalogue:


⤓ SafeAir Range | Short Catalogue

 

 

The post SafeAir (GP) appeared first on Medem UK Ltd..

]]>
> Compact <
> Engineers features <
> 1 to 4 detectors <
> OLED display <
> Simple to install <
> Settable SELV relay (Low/High Alarm, Detector Alert, EM stop & Gas On conditions) <
> EM stop & Fire Alarm monitoring <

Panel mounted Emergency Stop Button with facility to monitor remote buttons.
Patented gas pressure proving method.

 


Product and Installation Guides
⤓ SafeAir (GP) | Product and Installation Guide



Related Standards
 > BS6173
 > UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post SafeAir (GP) appeared first on Medem UK Ltd..

]]>
BGP-Y https://medem.co.uk/product/remote-emergency-stop-buttons/ Wed, 20 Feb 2019 12:21:48 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=1006 Remote stop buttons supplied by Medem.

Remote Stop Buttons can be installed with all our systems for convenience and safety. To find out more about the product please download the 'EM-Stop Wiring details'.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

 

The post BGP-Y appeared first on Medem UK Ltd..

]]>
 


Product and Installation Guides
⤓ EM-Stop | Product and Installation Guide

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post BGP-Y appeared first on Medem UK Ltd..

]]>
Gas Detectors https://medem.co.uk/product/gas-detectors/ Wed, 20 Feb 2019 10:08:18 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=999 The Medem's Gas Detectors are addressable gas detectors for use with our systems and we produce a range of gas detectors for use with various control systems in our range.

IMPORTANT – Gas Detectors should not be installed until all building, construction or painting work, etc. Is completed, as these works can affect the sensitivity and longevity of the detectors.

Currently, they include:

  • Methane CH4 (natural gas)
  • Propane C3H8 (LPG)
  • Carbon Monoxide (CO)
  • Carbon Dioxide (CO2)
  • Oxygen O2 (both for enrichment and depletion)
  • Hydrogen (H)
  • Chlorine (CL)
  • Nitrogen Dioxide (NO2)
  • Hydrogen Sulphide (H2S)

Coming soon:

  • Ammonia (NH3)
  • Acetylene (C2H2)
  • Phosphine (PH3
  • Pentene (C5H10)

Detector Siting
When considering the placement of fixed-point gas detectors several factors must be taken into consideration including (but not limited to):

  • The gas type.
  • What the potential source is.
  • The shape of the area i.e. roof peaks or sunken areas).
  • Obstructions that could lead to “dead spaces”.
  • Thermal links, remote EM stop buttons and a fire alarm input can all be monitored.
  • Airflow – either natural or mechanical.

The underlying point is that the gas must reach the sensor in order for it to be detected, therefore each installation must be considered on its own merits and the information contained here is to be used as guidance only.

Carbon Dioxide
Medem's CO2 detection is designed to deal with its production either via cooking or biological processes (namely breathing).
CO2 is roughly equal weight and density as air it will therefore naturally diffuse equally within a space. Our CO2 detectors are for the purpose of monitoring the air quality within an area to ensure adequate ventilation is taking place, as such the detectors should be located with the main body of the room within the “breathing zone” (4 to 8 feet) but not in such a place they'd likely be exposed to a potential release point (i.e. someone breathing on it). The alarm levels are dependent on application with different levels being specified for education facilities and for commercial kitchens, these are set within Medem's control panels and not the detector themselves.

Methane
A colourless gas which is a lighter than air gas and will, therefore, tend to rise when released to the atmosphere. Detector location should be at a high level. Detectors are set to alert at a pre-alarm level of 5% LEL and high-alarm of 10% LEL.

Propane
A colourless gas which is heavier than air gas and will therefore sink and stay at a low level when released to the atmosphere. Detector location should be at lower levels (approx 20 cm to 30cm from the floor). Detectors are set to alert at a pre-alarm level of 5% LEL and high-alarm of 10% LEL.

Carbon Monoxide
A colourless and odourless gas CO is roughly equal weight and density as air it will diffuse equally within a space. That said CO is typically produced as a product of poor combustion and as such can be initially excepted to rise as it will be hotter than the surrounding ambient temperature. Detector location is normally close by (but not immediately next to) the potential source – be that a boiler or ducted vent etc. Detectors are set to pre-alarm at 80ppm and high-alarm at 100ppm.

Oxygen
Oxygen forms some 21% of our atmosphere. At Medem, we primarily deal with oxygen depletion with a pre-alarm at 19% and high-alarm at 18%.
Although we have produced detectors for oxygen enrichment alarm levels would have to be decided on after discussion of the application.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

 

The post Gas Detectors appeared first on Medem UK Ltd..

]]>
> Methane CH4 (natural gas) <
> Propane C3H8 (LPG) <
> Carbon Monoxide (CO) <
> Carbon Dioxide (CO2) <
> Oxygen O2 (both for enrichment and depletion) <
> Hydrogen (H) <
> Chlorine (CL) <
> Nitrogen Dioxide (NO2) <
> Hydrogen Sulphide <
> Ammonia (NH3) <
> Acetylene (C2H2) <
> Phosphine (PH3) <
> Pentene (C5H10) <

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post Gas Detectors appeared first on Medem UK Ltd..

]]>
SafeAir https://medem.co.uk/product/safeair/ Wed, 20 Feb 2019 00:58:34 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=987 The SafeAir offers a simple cost-effective panel for ventilation interlocking in a commercial kitchen.

It is designed for use within commercial kitchens, to aid sites in meeting BS6173:2009 and IGEM/UP19. It can also monitor for air quality when fitted with the required detectors with carbon dioxide PPM levels displayed on the LCD.

The easy to use LCD provides clear messages giving real-time information rather than just LED indications.

It is a requirement that any mechanical ventilation within a kitchen environment (both supply and extract) is switched on and running before the use of any gas appliances can take place. With the SafeAir if the ventilation is not switched on, the LCD display informs the operator that the fans are off.

For the interlocking of the ventilation, our current monitoring units (CM2M-K or CM2L-K) or pressure differential switches can be used.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

Download the catalogue:


⤓ SafeAir Range | Short Catalogue

 

 

The post SafeAir appeared first on Medem UK Ltd..

]]>
> Compact <
> 1 to 4 detectors <
> OLED display <
> Simple to install <
> Settable SELV relay (Low/High Alarm, Detector Alert, EM stop & Gas On conditions) <
> EM stop & Fire Alarm monitoring <

Panel mounted Emergency Stop Button with facility to monitor remote buttons.

 


Product and Installation Guides
⤓ SafeAir | Product and Installation Guide



Related Standards
 > BS6173
> UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post SafeAir appeared first on Medem UK Ltd..

]]>
FTIP-1 https://medem.co.uk/product/ftip-1/ Wed, 20 Feb 2019 00:54:15 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=985 The FTIP-1 is a fire test isolation panel made by Medem.

All Medem control panels have the capacity to be connected to a fire panel, so in the event of an alarm, our systems can isolate the gas supply.

Although a vital safety feature it can prove inconvenient when testing and servicing the fire alarm system.

The FTIP-1 is designed to sit between our standard gas control systems and the fire alarm panel. When activated it will isolate the two systems from each other allowing the fire alarm to be tested without interrupting the gas supply.

This is a key controlled and timed (max 45 min) isolation, that if not manually reset will do so automatically after the period set during installation.

Please Note:
FTIP-1 function is built into the SEC range of panels.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

 

The post FTIP-1 appeared first on Medem UK Ltd..

]]>
> Compact <
> Time Adjustable <
> Key Control <
> Can isolate multiple Medem panels <

 


Product and Installation Guides
⤓ FTIP-1 | Product and Installation Guide

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post FTIP-1 appeared first on Medem UK Ltd..

]]>
CM2M-K https://medem.co.uk/product/cm2m-k/ Wed, 20 Feb 2019 00:53:47 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=984 The CM2M-K is a current monitor designed for use with Medem ventilation interlock systems.

Flexibility
Each CM2M-K can be used to interlock 2 fans, the fans are connected by taking the live feed for each fan through the current monitor (before any speed controllers/inverters).

Fan load sensitivity range on each fan is 30 milliamps to 24 amps (max).

Features and Details:

  • There are 3 LED indications:
       > 1x Green, for the 12-volt power to the CM2M-K.
       > 2x Red, one for 'Fan A' and another for 'Fan B' load detection.

When the fans are switched on and the load is detected (installation instructions) the corresponding side’s NO/NC contact will close and the red LED will light, this will flash for the first 15 minutes after current detection and then become solid. The flashing LED helps us to identify a fan intermittently stalling.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

 

The post CM2M-K appeared first on Medem UK Ltd..

]]>
> Compact <
> LED sequence to aid intermittent fan fault identification <
> Wide monitoring range <
> Multiple units can be series wired <

Large sensitivity range, 30 milliamps to 24 amps (max).
Can be used with 3 phase by selecting a single phase to monitor.

 


Product and Installation Guides
⤓ CM2M-K | Product and Installation Guide

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post CM2M-K appeared first on Medem UK Ltd..

]]>
VPS-K https://medem.co.uk/product/vps-k/ Wed, 20 Feb 2019 00:52:46 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=983 LEGACY PRODUCT ONLY

The VPS-K is a ventilation interlock system for use within commercial kitchens.

> This is a Ventilation Interlock System Only <

Very easy to use, the LCD displays clear messages giving real information rather than just LED indications.

It is a requirement that any mechanical ventilation within a kitchen environment (both supply and extract) is switched on and running before the use of any gas appliances can take place. With the VPS-K if the ventilation is not switched on, the LCD display informs the operator that the fans are off and to switch on the fans and restart the panel.

Please Note:
The VPS-K is one of our original range of interlock systems, consideration should be given to an integrated gas proving interlock system. – See our news article: Why choose Medem differential pressure proving?


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

 

The post VPS-K appeared first on Medem UK Ltd..

]]>
This product is no longer available. If you need assistance with an already installed unit, please get in touch and we’ll help.

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

 

The post VPS-K appeared first on Medem UK Ltd..

]]>