CO2 & Gas Detection Archives - Medem UK Ltd. https://medem.co.uk/product-category/commercial-kitchens/co2-gas-detection-commercial-kitchens/ Leading supplier and Manufacturer of Gas Detection equipment. Sun, 07 Jul 2019 19:40:26 +0000 en-GB hourly 1 https://wordpress.org/?v=6.4.3 https://medem.co.uk/wp-content/uploads/2018/10/cropped-Favacon-1-32x32.png CO2 & Gas Detection Archives - Medem UK Ltd. https://medem.co.uk/product-category/commercial-kitchens/co2-gas-detection-commercial-kitchens/ 32 32 SafeAir CM (GP) https://medem.co.uk/product/safeair-cm-gp/ Wed, 20 Feb 2019 14:13:47 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=1012 The SafeAir CM GP offers a simple single panel package for ventilation interlocking a commercial kitchen to aid sites in meeting BS6173:2009 and IGEM/UP19.

It can also monitor for air quality when fitted with the required detectors with carbon dioxide PPM levels displayed on the LCD.

It features gas pressure proving and built-in two-channel current monitor designed for use within commercial kitchens, set up with a simple button press.

Gas proving must be fitted in any commercial kitchen which has appliances fitted without flame failure devices (FFD’s). As explained further in the article “why fit gas pressure proving in a commercial kitchen?” gas proving should be considered for the long term benefit and safety of the site when considering other gas standards and that the majority of leaks identified are before the FFD’s.

The easy to use OLED provides clear messages giving real-time information rather than just LED indications.

Fan load sensitivity range on each fan is 30 milliamps to 20 amps (max).


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

Download the catalogue:


⤓ SafeAir Range | Short Catalogue

 

 

 

The post SafeAir CM (GP) appeared first on Medem UK Ltd..

]]>
> In-built two-channel current monitoring <
> Simple button press learn feature for current monitoring set-up <
> Gas proving with Engineers features <
> 1 to 4 detectors <
> OLED display <
> Settable SELV relay (Low/High Alarm, Detector Alert, EM stop & Gas On conditions) <
> EM stop & Fire Alarm monitoring <

Panel mounted Emergency Stop Button with a facility to monitor remote buttons.


Product and Installation Guides
⤓ SafeAir CM (GP) | Product and Installation Guide



Related Standards
 > BS6173
 > UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post SafeAir CM (GP) appeared first on Medem UK Ltd..

]]>
SafeAir CM https://medem.co.uk/product/safeair-cm/ Wed, 20 Feb 2019 13:23:12 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=1010 The SafeAir CM offers a simple single panel package for ventilation interlocking a commercial kitchen to aid sites in meeting BS6173:2009 and IGEM/UP19.

The SafeAir CM offers a simple single panel package for ventilation interlocking a commercial kitchen to aid sites in meeting BS6173:2009 and IGEM/UP19.

It can also monitor for air quality when fitted with the required detectors with carbon dioxide PPM levels displayed on the LCD.

It features built-in two-channel current monitor designed for use within commercial kitchens, set up with a simple button press.

The easy to use OLED provides clear messages giving real-time information rather than just LED indications.

Fan load sensitivity range on each fan is 30 milliamps to 20 amps (max).


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

Download the catalogue:


⤓ SafeAir Range | Short Catalogue

 

 

The post SafeAir CM appeared first on Medem UK Ltd..

]]>
> In-built two channel current monitoring <
> Simple button press learn feature for current set-up <
> Engineers features <
> 1 to 4 detectors <
> OLED display <
> Settable SELV relay (Low/High Alarm, Detector Alert, EM stop & Gas On conditions) <
> EM stop & Fire Alarm monitoring <

Panel mounted Emergency Stop Button with facility to monitor remote buttons.

 


Product and Installation Guides
⤓ SafeAir CM | Product and Installation Guide



Related Standards
 > BS6173
 > UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post SafeAir CM appeared first on Medem UK Ltd..

]]>
SafeAir (GP) https://medem.co.uk/product/safeair-gp/ Wed, 20 Feb 2019 13:13:04 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=1008 The SafeAir (GP) offers a simple cost-effective panel for ventilation interlocking and gas pressure proving in a commercial kitchen.

It is designed for use within commercial kitchens, to aid sites in meeting BS6173:2009 and IGEM/UP19. It can also monitor for air quality when fitted with the required detectors with carbon dioxide PPM levels displayed on the LCD.

Gas proving must be fitted in any commercial kitchen which has appliances fitted without flame failure devices (FFD’s). As explained further in the article “why fit gas pressure proving in a commercial kitchen?” gas proving should be considered for the long-term benefit and safety of the site when considering other gas standards and that the majority of leaks identified are before the FFD’s.

The easy to use LCD provides clear messages giving real-time information rather than just LED indications.

It is a requirement that any mechanical ventilation within a kitchen environment (both supply and extract) is switched on and running before the use of any gas appliances can take place. With the SafeAir (GP), if the ventilation is not switched on, the LCD display informs the operator that the fans are off.

For the interlocking of the ventilation, our current monitoring units (CM2M-K or CM2L-K) or pressure differential switches can be used.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

Download the catalogue:


⤓ SafeAir Range | Short Catalogue

 

 

The post SafeAir (GP) appeared first on Medem UK Ltd..

]]>
> Compact <
> Engineers features <
> 1 to 4 detectors <
> OLED display <
> Simple to install <
> Settable SELV relay (Low/High Alarm, Detector Alert, EM stop & Gas On conditions) <
> EM stop & Fire Alarm monitoring <

Panel mounted Emergency Stop Button with facility to monitor remote buttons.
Patented gas pressure proving method.

 


Product and Installation Guides
⤓ SafeAir (GP) | Product and Installation Guide



Related Standards
 > BS6173
 > UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post SafeAir (GP) appeared first on Medem UK Ltd..

]]>
SafeAir https://medem.co.uk/product/safeair/ Wed, 20 Feb 2019 00:58:34 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=987 The SafeAir offers a simple cost-effective panel for ventilation interlocking in a commercial kitchen.

It is designed for use within commercial kitchens, to aid sites in meeting BS6173:2009 and IGEM/UP19. It can also monitor for air quality when fitted with the required detectors with carbon dioxide PPM levels displayed on the LCD.

The easy to use LCD provides clear messages giving real-time information rather than just LED indications.

It is a requirement that any mechanical ventilation within a kitchen environment (both supply and extract) is switched on and running before the use of any gas appliances can take place. With the SafeAir if the ventilation is not switched on, the LCD display informs the operator that the fans are off.

For the interlocking of the ventilation, our current monitoring units (CM2M-K or CM2L-K) or pressure differential switches can be used.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

Download the catalogue:


⤓ SafeAir Range | Short Catalogue

 

 

The post SafeAir appeared first on Medem UK Ltd..

]]>
> Compact <
> 1 to 4 detectors <
> OLED display <
> Simple to install <
> Settable SELV relay (Low/High Alarm, Detector Alert, EM stop & Gas On conditions) <
> EM stop & Fire Alarm monitoring <

Panel mounted Emergency Stop Button with facility to monitor remote buttons.

 


Product and Installation Guides
⤓ SafeAir | Product and Installation Guide



Related Standards
 > BS6173
> UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post SafeAir appeared first on Medem UK Ltd..

]]>
VGPS-evo https://medem.co.uk/product/vgps-evo/ Wed, 20 Feb 2019 00:52:00 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=982 The VGPS-evo offers ventilation interlocking, gas pressure proving and environmental monitoring in a single panel for use within commercial kitchens helping them meet the requirements of BS 6173:2009 and IGEM/UP19.

Very easy to use, the LCD displays clear messages giving real information rather than just LED indications.

Medem gas detectors can be used to monitor the carbon dioxide level to ensure that HSE set levels are not exceeded.

Engineer functions can be used to aid in the setup of the system –displaying real-time inlet and outlet pressure at the gas valve (mbar) Valve lift button, it’s with functions like these that for example a 'valve let by indication' check be performed with ease.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

 

The post VGPS-evo appeared first on Medem UK Ltd..

]]>
> Gas Pressure Proving <
> Ventilation Interlock <
> Carbon Dioxide Level Monitoring <
> Carbon Monoxide Detection <
> Engineer Functions <
> Over Pressure Alert <

The fail-safe gas valve and relay checking are just some of the new developments making Medem systems continue to be the most reliable, safest and flexible available today.

 


Product and Installation Guides
⤓ VGPS-evo | Product and Installation Guide



Related Standards
> BS6173
> UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

The post VGPS-evo appeared first on Medem UK Ltd..

]]>
SEC-K https://medem.co.uk/product/sec-k/ Tue, 19 Feb 2019 20:53:05 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=966 The SEC-K is a ventilation interlock and gas proving system for commercial kitchens with multiple in-built features which can be used where and when required to help sites meet BS6173/2009 & IGEM UP19.

The recently updated V4 system can monitor for carbon monoxide (CO) and carbon dioxide (CO2) out-of-hours so even when the panel is switched off an alarm can be raised, or ventilation switched on. This provides additional safety monitoring particularly if solid fuel appliances are installed within the kitchen.

Gas proving must be fitted in any commercial kitchen which has appliances fitted without flame failure devices (FFD’s). As explained further in the article “why fit gas pressure proving in a commercial kitchen?” gas proving should be considered for the long-term benefit and safety of the site when considering other gas standards and that the majority of leaks identified are before the FFD’s.

Demand-controlled ventilation fail-safe gas valve and relay checking are just some of the new developments making Medem systems continue to be the most reliable, safest and flexible available today.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

 

The post SEC-K appeared first on Medem UK Ltd..

]]>
> Gas Pressure Proving <
> Ventilation Interlock <
> Carbon Dioxide Level Monitoring <
> Carbon Monoxide Detection <
> Demand Controlled Ventilation <
> Fire Test Isolation Control Built-in <
> Out-of-hours CO Monitoring and Alarm <
> Electrical Isolation <
> Engineer Functions <
> Fan interlocking <
> Fire Test Isolation Mode <
> Over Pressure Alert <

Settable relays for BMS, beacon or fan activation.

Low Alarm • High Alarm • Emergency Stop • Gas On/Off • Fire Panel Activated • Detector Fault • Generic Alarm

 


Product and Installation Guides
⤓ SEC-K | Product and Installation Guide



Related Standards
 > BS6173
> UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

 

The post SEC-K appeared first on Medem UK Ltd..

]]>
SEC-K (NP) https://medem.co.uk/product/sec-k-np/ Tue, 19 Feb 2019 16:51:23 +0000 https://medem.co.uk.gridhosted.co.uk/?post_type=product&p=962 The SEC-K is a ventilation interlock system for commercial kitchens with multiple in-built features which can be used where and when required to help sites meet BS 6173/2009 & IGEM UP19.

The recently updated V4 system can monitor for carbon monoxide (CO) and carbon dioxide (CO2) out of hours so even when the panel is switched off an alarm can be raised, or ventilation switched on. This provides additional safety monitoring particularly if solid fuel appliances are installed within the kitchen.

Demand-controlled ventilation fail-safe gas valve and relay checking are just some of the new developments making Medem systems continue to be the most reliable, safest and flexible available today.


If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

The post SEC-K (NP) appeared first on Medem UK Ltd..

]]>
> Ventilation Interlock <
> Carbon Dioxide Level Monitoring <
> Carbon Monoxide Gas Detection <
> Demand Controlled Ventilation <
> Dual BMS selectable relays <
> Fire Test Isolation Control Built-in <
> CO2 based ventilation activation <
> CO2 based ventilation control <
> Electrical Isolation <
> Engineer Functions <
> Fan interlocking <

Out of hours CO and CO2 monitoring, fail-safe gas valve and relay checking are just some of the new developments making Medem systems continue to be the most reliable, safest and flexible available today.

 


Product and Installation Guides
⤓ SEC-K (NP) | Product and Installation Guide



Related Standards
 > BS6173
 > UP19

 


All our products come with a 5-year warranty
Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of its products.
This applies to the main panels and sender units, gas detectors carry a 2-year warranty.

Why not let us install your system and receive a 10-year Warranty?
Where we’ve commissioned an installed system, the warranty is extended from five to ten years. At the time of commissioning, photos and gas pressure readings are recorded along with other relevant details of the installation. A 24-hour helpline number and the serial number is attached with the panel and all details are then entered on to the Medem database.

 

The post SEC-K (NP) appeared first on Medem UK Ltd..

]]>